尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China User Manual for CMS54 Integrated Tester - China Supplier
China User Manual for CMS54 Integrated Tester - China Supplier China User Manual for CMS54 Integrated Tester - China Supplier China User Manual for CMS54 Integrated Tester - China Supplier China User Manual for CMS54 Integrated Tester - China Supplier China User Manual for CMS54 Integrated Tester - China Supplier

User Manual for CMS54 Integrated Tester

Price:12000
Industry Category: Instruments & Meters/Laboratory Instrument Devices/Other Lab Instruments
Product Category:
Brand:
Spec:


Contact Info
  • Address:深圳市龍華區(qū)清湖華清大道200號(hào)半里大廈1807, Zip: 518131
  • Contact: 姚紅娟
  • Tel:18025363925
  • Email:alina@maikairui.com

Other Products

Description
Additional Information

CMS54 Comprehensive Tester User Guide Rohde & Schwarz CMS54 CMS54 CMS54

CMS54 Operation Instructions

I. Level Measurement Operation Steps
1. Turn on the spectrum analyzer;
2. Press the mode selection "Mode" key on the left side of the key matrix, and a column of mode options appears on the right side of the LCD screen;
3. Click the button on the right side of the LCD screen corresponding to "Spectrum Analyzer" to enter the spectrum measurement mode;
4. Press the "Meas" key in the lower left corner of the key matrix (i.e., the measurement item selection key), and a column of test options appears on the right side of the LCD screen;


5. Click the right button corresponding to "Channel Power" to enter the level measurement interface;
6. Press the "Meas Setup" key on the key matrix, and a column of level detection settings appears on the right side of the LCD screen;
7. Click the right button corresponding to "Integ BW" (i.e., representing the measurement bandwidth), enter the bandwidth of the measured frequency point on the numeric keypad. At this time, a column of units appears on the LCD screen. Click the right button corresponding to the desired unit (for example, if the bandwidth of the measured frequency point is 8MHz, click 8 on the numeric keypad, then click the right button corresponding to MHz on the LCD screen);
8. Press the "FREQ Channel" key on the key matrix, and a column of frequency setting options appears on the right side of the LCD screen;
9. Click "Center FREQ", type the center frequency of the measured frequency point on the numeric keypad. At this time, a column of units appears on the LCD screen. Click the right button corresponding to the desired unit;
10. The level of the measured frequency point is displayed in the lower left corner of the LCD screen, in the format of "*dBm/8MHz", representing the power within 8MHz;
11. If the power value does not meet expectations, you can try pressing the "AMPTD" key on the key matrix, then click "Attenuation", and press the calibration button to calibrate the level measurement value.
II. Spurious Output Suppression Ratio (Out-of-Band Suppression) Measurement Operation Steps
1. Turn on the spectrum analyzer;
2. Press the mode selection "Mode" key on the left side of the key matrix, and a column of mode options appears on the right side of the LCD screen;
3. Click the button on the right side of the LCD screen corresponding to "Spectrum Analyzer" to enter the spectrum measurement mode;
4. Press the "Meas" key in the lower left corner of the key matrix (i.e., the measurement item selection key), and a column of test options appears on the right side of the LCD screen;
5. Click the right button corresponding to "Swept SA" to enter the spectrum measurement interface;
6. Press the "FREQ Channel" key, and a column of frequency setting options appears on the right side of the LCD screen;
7. Click the right button corresponding to "Start FREQ", and enter 45 through the numeric keypad. At this time, a column of units appears on the right side of the LCD screen, from top to bottom: "GHz", "MHz", and "Hz". Click the right button corresponding to "MHz";
8. Click the right button corresponding to "Start FREQ", and enter 1 through the numeric keypad. At this time, a column of units appears on the right side of the LCD screen, from top to bottom: "GHz", "MHz", and "Hz". Click the right button corresponding to "GHz". Through steps 7~8, the spectrum measurement range is set to 45MHz~1GHz;


9. Press the "Trace/" key on the key matrix, and a column of options appears on the right side of the LCD screen;
10. Click the right button corresponding to "Trace Average" to set the spectrum display to average mode;
11. Press the "BW" key on the key matrix, and a column of options appears on the right side of the LCD screen;
12. Click the right button corresponding to "Res BW" so that "Man" under "Res BW" on the LCD screen is selected;
13. Then enter 100 through the numeric keypad. At this time, a column of units appears on the right side of the LCD screen. Click the right button corresponding to "KHz"; (Through steps 9~13, the out-of-band measurement is made more accurate)
14. Press the "Marker" key on the key matrix;
15. Press the "Peak Search" key on the key matrix. The marker point is displayed on the spectrum point on the LCD screen, and a column of options appears on the right side of the LCD screen;
16. Click the right button of "Marker Delta", then rotate the rotary button in the key matrix left or right

Rohde & Schwarz CMS54 Radio Comprehensive Tester CMS54

CMS54

Main Features
The wireless communication maintenance tester CMS series consists of four modules. These wireless testers allow for transmitter, receiver, and duplex measurements on mobile broadcasting equipment, base stations, or RF modules.

The CMS series monitors are ideal wireless testers for maintenance, service, and testing departments.
CMS – CMS54 can replace many single measurement instrument test setups
Due to the complex standard configuration of individual modules and the customizable option extensions for specific applications, external measurement instruments outside CMS are no longer needed.
Module Overview
CMS50
Budget-priced module for maintenance applications:
◆ Transmitter and receiver testing
◆ Spectrum monitoring


◆ Fully automated testing
◆ SSB testing
◆ ERMES encoder
CMS54 –
For high-demand testers:
Same wireless measurements and option extensions as CMS52
Additional basic modules include:
◆ Full-range tracking generator from 0.4 to 1000MHz
◆ Adjacent channel power meter with ETSI filter
◆ Duplex modulation tester
◆ Automatic harmonic measurement
◆ Cable fault testing

CMS54 Features

Portable multifunctional test instrument

Industry Category: Instruments & Meters/Laboratory Instrument Devices/Other Lab Instruments
Product Category:
Brand:
Spec:
Stock:
Origin:
Storefront Language: English English Chinese
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 钟祥市| 桐梓县| 兴文县| 无锡市| 焦作市| 九江市| 海林市| 黑龙江省| 红原县| 南投市| 廉江市| 沅江市| 平原县| 平谷区| 将乐县| 唐山市| 都江堰市| 松滋市| 亳州市| 灵川县| 康保县| 金乡县| 伊宁市| 金门县| 临湘市| 南宫市| 临泉县| 澄江县| 南华县| 莒南县| 大邑县| 普安县| 石阡县| 石屏县| 贵州省| 巴南区| 韶关市| 大冶市| 青田县| 酉阳| 贵德县|