Bacterial Toxin Luminescence Detector HSK-D760 Hongsenkai Bacterial Toxin Luminescence Detector HSK-D760, Hubei Hongsenkai Biotechnology Co., Ltd. is dedicated to bacterial toxin luminescence detection; this Bacterial Toxin Luminescence Detector HSK-D760 is easy to operate and provides accurate results.

Introduction to the Bacterial Toxin Luminescence Detector HSK-D760:
In the field of bacterial toxin luminescence detection, the contradiction between measurement accuracy and speed has long remained unresolved; addressing this situation, a bacterial toxin luminescence detector based on bio-fluorescence sensing technology is provided, supplementing the domestic field of rapid bacterial toxin luminescence detection instruments; this instrument automatically analyzes sample data based on changes in luminescence intensity during the metabolism of luminescent bacteria; compared to traditional biological detection methods using fish, daphnia, and other aquatic organisms, the luminescent bacteria method is simple, fast, sensitive, adaptable, reproducible, precise, cost-effective, and widely applicable, designed for rapid water toxicity detection in environmental pollution, emergencies, security checks, and routine monitoring; strictly complies with GB/T 15441-1995 Water Quality—Determination of Acute Toxicity—Luminescent Bacteria Method; can be used for on-site detection of overall toxicity of substances such as heavy metals, toxic agents, nerve agents, pesticides, etc., in water.

Application Scope:
1. Wide range of applications, capable of monitoring various water bodies; such as rivers, streams, lakes, reservoirs, restaurant wastewater, laboratory waste liquids, industrial wastewater, polluted water bodies, and toxicity testing of various actual water samples under laboratory conditions for soluble chemicals.

Instrument Functions:
1. Display Screen: 7-inch LCD touch display;
2. Operating System: Android 9.0 operating system, 2G+16G (built-in TF memory supports expansion up to 128G);
3. Detection Standard: National Standard GB/T 15441-1995;
4. Detection Range: Can detect heavy metal ions, organic pesticides, organic and inorganic toxic substances, etc.;
5. User Information: Can set the testing unit name and testing personnel;
6. User Information: Name of the tested unit, sampling address, sampling time;
7. Detection Information: Test results, result judgment, detection time;
8. Sampling Location: Supports automatic location acquisition for the testing site;
9. Data Analysis: Statistical summary analysis of test results through periodic pie charts, bar charts, and line charts;
10. Data Export: Supports USB data export, with optional formats (TXT, Excel);
11. Instrument Lifespan: Uses imported LED light sources, leakage protection, voltage-stabilizing adapters, etc., with an instrument lifespan of over 10 years;
12. Printing Function: Built-in 58mm thermal printer, printing information includes sample information, user information, and detection information;
13. Video Assistance: Built-in operational video steps to assist in learning and operation;
14. Data Upload: Supports result upload to data platforms, as well as distribution and feedback of testing tasks;
15. Communication Interfaces: SIM card slot (supports all networks), TF memory expansion slot, RS232, Type A USB, Type B USB, Ethernet port, Wi-Fi, Bluetooth.
Technical Parameters:
1. Detection Channel: Single channel;
2. Detection Principle: Luminescent bacteria method;
3. Detection Range: Overall toxicity detection of over 6,000 substances such as heavy metals, toxic agents, nerve agents, pesticides, etc., in water;
4. Detection Results: Detection value (mg/L), toxicity prompt (low toxicity, moderate toxicity, high toxicity, severe toxicity, extreme toxicity);
5. Detection Time: Three modes optional: 5 minutes, 15 minutes, 30 minutes;
6. Result Error: ≤±5%;
7. Instrument Dimensions: 235*287*200 (mm).

The above is an introduction to the Bacterial Toxin Luminescence Detector HSK-D760, as well as its functions and technical parameters; if you would like to learn more about the Bacterial Toxin Luminescence Detector HSK-D760, please contact Hubei Hongsenkai Biotechnology Co., Ltd.

: Instruments & Meters/Laboratory Instrument Devices/Other Lab Instruments
:
Brand:
:
Stock:
Origin:
About Toocle.com -  Toocle Partnership -  Toocle Services -  Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 滦南县| 兰西县| 平泉县| 平定县| 射阳县| 张家港市| 仲巴县| 昆明市| 敦化市| 佳木斯市| 莆田市| 河曲县| 酒泉市| 确山县| 河北省| 扬中市| 渝北区| 鹤山市| 旬邑县| 新源县| 柳河县| 宝丰县| 分宜县| 绥阳县| 大姚县| 察雅县| 昭通市| 宜州市| 忻城县| 天门市| 莱阳市| 调兵山市| 满洲里市| 沛县| 广灵县| 山西省| 沙雅县| 永顺县| 栾川县| 喀喇沁旗| 武邑县|