OLT-55 Intelligent Optical Loss Tester Features

· Multi-functional integration: Stable light source + Optical power meter + Loss tester + Return loss test + Length test

· Power test function

· Single fiber bidirectional loss test

· Automatic wavelength identification/switching

· Remote reference value setting

· Pass/Fail judgment setting

· FTTx/PON network applications

· Built-in clock, with editable test cable and fiber sequence number

· USB interface for charging and data upload

· Generates test reports for easy data archiving

· 1000 records storage and management, supports CSV format

· Built-in rechargeable battery allows continuous testing for over 35 hours

· Handheld, compact and portable, easy to operate

· No warm-up required, quick start

· High-resolution color LCD

· Certified by CE, FCC, etc.

The OLT-55 series intelligent optical loss tester integrates a stable light source and optical power meter, featuring an automatic single-fiber bidirectional loss test mode. Combined with Pass/Fail judgment settings, it enhances ease of use and convenience in practical applications while reducing the probability of operational errors.

The OLT-55's rugged and user-friendly design makes it widely applicable in optical network fields such as FTTX, LAN, and CATV. It is a product designed for verifying optical network link loss.

Automatic Single-Fiber Bidirectional Loss/Return Loss Test Option

By connecting one OLT-55 at each end of the same fiber, a single-key operation enables bidirectional link loss/return loss testing on a single fiber. It automatically calculates and displays the average loss of the tested fiber and the total link length, providing customers with optical link loss assessment information.

Automatic Wavelength Identification/Switching

The optical power module of the OLT-55 series optical loss tester can automatically identify wavelength identification signals with digital encryption protocols emitted by its stable light source or any Sinwav SLS-50 series stable light source, and switch to the corresponding wavelength for testing. This function significantly reduces communication needs between test operators and minimizes potential errors.

Suitable for FTTx/PON Testing

The OLT-55 series can be used for certification and routine maintenance of passive optical networks (PON), enabling convenient testing at 1310nm, 1490nm, and 1550nm wavelengths.

Optical Power Test Function

The OLT-55 can test changes in optical power over a period of time and record them in the form of curves.

OLT-55 Series Optical Loss Tester Technical Specifications

Model

OLT-55

Stable Light Source

Wavelength(±20nm)

1310/1550

1310/1490/1550

1310/1550/1625

Spectral Width

≤5nm

Output Power

>-4dBm

Stability

±0.05dB/15 minutes; ±0.10 dB/8 hours

Output Mode

CW, 270Hz, 1kHz, 2kHz

Optical Power Meter

Calibration Wavelength (1)

850, 1300, 1310, 1490, 1550, 1625nm

Test Range (2)

-70~+10dBm

-50~ +27dBm

Unit

W/mW/μW/nW/pW/dBm/dB(REF)

Detector Type

InGaAs

Accuracy

±5%±0.01nW (±0.5 dB@850nm)

±5%±1nW(±0.5 dB@850nm)

Resolution

0.01dB

Automatic Wavelength Identification

Yes (when used with specific stable light sources from our company)

Modulated Wave Identification

270, 1K, 2KHz

Optical Loss Test

Link Loss Range

50dB (1550nm, 200km)

Link Loss Test Accuracy

±0.25dB

Link Loss Test Time

< 2 seconds/wavelength

Optical Return Loss Test (Option)

Return Loss Test Range

0~60dB (APC connector)

Return Loss Test Accuracy

±0.75dB@(0~50dB), ±1.5dB@(50~60dB)

Return Loss Test Stability

±0.5dB@20dB

General Specifications

Optical Interface

FC (interchangeable with SC, ST, etc.)

Data Storage

1000 sets

Data Interface

USB

Backlit Display

Yes

Auto Power Off

Automatically turns off after 5 minutes of inactivity

Power Supply

Lithium battery, AC adapter/charger

Battery Operating Time

Continuous testing time ≥35 hours

Operating Temperature

-20℃ to 50℃

Storage Temperature

-40℃ to 70℃

Relative Humidity

0 to 95% (non-condensing)

Weight

350g

Dimensions (L×W×H)

177×80×44mm

Note: (1) Other calibration wavelengths can be customized according to user requirements;

(2) The lower limit of the test range for the 850nm wavelength is: -60 dBm.

The above parameters are subject to change without notice.

OLT-55 Series Optical Loss Tester Standard Configuration:

Main unit, lithium battery, AC adapter/charger, USB data cable, software CD, simple portable soft case, warranty card, CE certificate, calibration certificate, user manual.

: Instruments & Meters/Laboratory Instrument Devices/Other Lab Instruments
:
Brand:
:
Stock:
Origin:
About Toocle.com -  Toocle Partnership -  Toocle Services -  Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 个旧市| 武威市| 定西市| 邵阳市| 聊城市| 定日县| 永春县| 原平市| 闻喜县| 六盘水市| 大足县| 上蔡县| 怀宁县| 曲水县| 威远县| 平泉县| 辽宁省| 呈贡县| 赤壁市| 黄龙县| 芮城县| 阿瓦提县| 中牟县| 建德市| 安泽县| 区。| 西充县| 商城县| 青河县| 丰都县| 巴林右旗| 会同县| 万山特区| 江门市| 都安| 仁寿县| 山西省| 北京市| 民乐县| 土默特右旗| 楚雄市|