尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China Portable Trace Moisture Analyzer EDM-P - China Supplier
China Portable Trace Moisture Analyzer EDM-P - China Supplier

Portable Trace Moisture Analyzer EDM-P

Price:Negotiable
Industry Category: Instruments & Meters/Specialized Instruments/Other Specialized Instruments
Product Category:
Brand: alpha
Spec: EDM-P


Contact Info
  • Add:北京市昌平區(qū)建材城西路87號(hào)院上奧世紀(jì)2A1602, Zip:
  • Contact: 王先生
  • Tel:18610010238
  • Email:18610010238@163.com

Other Products

Description
Additional Information

Portable Trace Moisture Analyzer EDM-P

The Portable Trace Moisture Analyzer EDM-P utilizes a phosphorus pentoxide sensor to absorb moisture, electrolyzing water molecules into hydrogen and oxygen, and measures the electrical charge required for this electrolysis. The electrolytic hygrometer was invented in 1956 and can detect gas moisture content as low as a few parts per million, hence it is also known as a trace moisture analyzer. This instrument operates on the principle of water electrolysis, decomposing the moisture absorbed by phosphorus pentoxide into hydrogen and oxygen. According to Faraday's law, the charge required to electrolyze one gram-equivalent of water (9.01 grams) is 96,500 coulombs, which is why it is also referred to as a coulometric electrolytic hygrometer.

The measurement range of this instrument is typically 0~10~1000 ppm (dew point -76~-20°C). It is suitable for determining trace moisture in air, inert gases, hydrocarbons, and other gases that do not react with phosphorus pentoxide. It is widely used in chemical, petrochemical, electronics, metallurgical industries, and refrigeration engineering.

1. Working Principle

This instrument operates on continuous sampling based on hygroscopic electrolysis. When the gas sample flows through a specially designed electrolytic cell, the moisture is entirely absorbed by the phosphorus pentoxide acting as a desiccant, producing phosphoric acid solution:

P2O3+H2O→2HPO3

When a direct current is applied to the platinum electrodes in the electrolytic cell, the phosphoric acid is electrolyzed to produce hydrogen and oxygen, regenerating phosphorus pentoxide:

4HPO3→2H2+O2+2P2O2

During continuous measurement, the absorption and electrolysis processes occur simultaneously in the electrolytic cell. According to Faraday's law, the electrolysis current I equals:


Where I—electrolysis current (amperes);

mw—mass of water electrolyzed (grams);

N—chemical equivalent of water;

t—electrolysis time (seconds).

If the measured gas is a mixture of water vapor (mass mw, volume Vw) and dry gas (mass mw, volume Vw), then:


Where MW and Mg—molecular weights of water and dry gas

Substituting mW into equation (3.2) gives:


At a flow rate of 100 mL/min, temperature of 25°C, and pressure of one atmosphere, the electrolysis current for 1 ppm is 13.2 microamperes. To ensure accurate instrument readings, flow rate, temperature, and pressure must remain stable, and the electrolytic cell must fully absorb the moisture in the gas stream.

2. Electrolytic Cell Construction

The electrolytic cell typically has two different structural forms: one is internally wound, and the other is externally wound, as shown in Figures 3.1 and 3.2.


Features

EDM-P can select two gas inlets, independently processing moisture content from two gas streams.

Full-color touch LCD screen.

Display can be set to show PPM (V) or Celsius (dew point).

Built-in support for 7 selectable languages.

Advanced menu operation.

Power and battery management.

USB port for data transmission.

The instrument is self-controlling.

European EP annotation.

Applications

Medical gases

Microelectronics

Chemical industry (corrosive acidic gases)

Heat treatment

Research institutes or universities

Remarks

EDM-P has been specifically designed with corrosion-resistant fittings and valves for measuring corrosive gases. All parts in contact with corrosive gases are made of PVDF material.

Performance

Lower detection limit per channel: 0.05 ppm (v)

Measurement range: 0-2000 ppm

Resolution: 0.1 ppm (v)

Sensor self-test

Analog output: 4-20 mA

Data logging: intervals from 2 seconds to 10 minutes

Battery life: approximately 5 hours when fully charged.

Dimensions: 15×25×35 cm

Weight: 6 kg (8 kg)

Measurement Unit

Valve body material: PVDF or stainless steel.

Sensor material: Pt electrodes wound on glass or ceramic substrate.

Measured gas flow rate: 20 Nl/h or 100 Nl/h

Measured gas temperature: +5…+65°C

Maximum input pressure to the cell: 200 mbar

Measurement accuracy: +/- 5% of value, minimum 0.4 ppm (v)

Response time for humid gas: <1 second. Return time, T90 <2 minutes. Reproducibility at 20 ppm (v): +/- 2%

Gas connection: 1/4 inch NPT threaded fitting

Measurement cell connection: 5-pin binder plug, sensor cable 0.5 m

Options

Flow meter, three-way valve, four-way valve, sensor can be housed in a dust-proof polypropylene case, dry gas.

Industry Category Instruments & Meters/Specialized Instruments/Other Specialized Instruments
Product Category
Brand: alpha
Spec: EDM-P
Stock: 5
Manufacturer:
Origin: China / Beijing / Changpingqu
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 临夏市| 汉源县| 历史| 荔浦县| 定结县| 南溪县| 阿拉善右旗| 辉县市| 定襄县| 保山市| 阿城市| 全南县| 巴南区| 张掖市| 丰原市| 阳原县| 英超| 甘南县| 建平县| 石台县| 郧西县| 通城县| 惠州市| 沙坪坝区| 静宁县| 噶尔县| 宁远县| 兰溪市| 佛坪县| 绵竹市| 通江县| 永吉县| 汶川县| 宿松县| 抚松县| 冷水江市| 乐业县| 清涧县| 酒泉市| 西安市| 阿尔山市|