DWYER Electromagnetic Flow Sensor IEF-SN-CND

The IEFB series is a field-adjustable insertion thermal energy meter that uses electromagnetic technology to accurately and reliably measure fluid velocity and energy consumption. The high-precision IEFB can be adjusted to fit pipe sizes from 4 to 10 inches (100 to 250 mm), while the standard-precision IEFB is suitable for pipe sizes from 4 to 36 inches (100 to 900 mm). The IEFB integrates a thermometer and a calculator into a single unit. The LCD display provides clear readings of meter values, including temperature and energy consumption, making it ideal for installation in chillers, boilers, and other heating and cooling applications. With high measurement accuracy and long service life, it minimizes annual operating costs. Additionally, it offers multiple output options, including selectable BACnet MS/TP or Modbus? RTU communication protocols via 2-wire RS-485, as well as standard analog, frequency, and alarm outputs. · Flexible field-configurable settings display (LCD integrated option or remote accessory A-IEF).

Monitoring chiller cooling output performance, DWYER Electromagnetic Flow Sensor IEF-SN-CND

The IEF series insertion electromagnetic flow transmitter is an adjustable insertion flow meter that, in addition to providing continuous signal output, employs electromagnetic technology for precise and reliable measurement of fluid velocity. This series is designed to deliver superior performance with simple installation and use. A single unit can be adjusted to fit pipe sizes from 4 to 36 inches (101.6 to 914.4 mm) and offers multiple output options, including selectable BACnet MS/TP or Modbus? RTU communication protocols, in addition to standard analog, frequency, and alarm outputs, communicating via 2-wire RS-485.
Field configurable, high precision, BACnet or Modbus protocol.

Medium: Compatible clean or dirty non-coating, conductive liquids.  

Range: 0-20 ft/s (0-6 m/s).

Wetted Materials: Body shaft/fittings: 316SS; Electrodes: 316SS; Electrode cover: Polymer/Polystyrene; O-ring: Silicone.

Accuracy: IEF-HX-K: ±0.5% of reading at calibrated velocity; ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s); ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s). IEF-SX-X: ±1% FS.

Temperature Resistance: Ambient: -20 to 160°F (-29 to 71°C); Process: 15 to 250°F (-9 to 121°C); Storage: -40 to 185°F (-40 to 85°C).

Connection: 1" NPT or BSPT with full-port ball valve option accessories.

Pressure Rating: 400 psi (27.6 bar) @ 100°F (37.8°C).

Pressure Drop: < 0.1 psi at 12 ft/s in 4" (101.6 mm) or larger pipes.

Output: (1) Analog: 4-20 mA, 0-5 V, 0-10 V, or 2-10 V (display selectable);

(2) Pulse/Frequency: 0-15 V pulse, 0-500 Hz, or adjustable output (display selectable);

(3) Alarm: (1) Empty pipe detection or minimum/flow velocity (display selectable); (2) Reverse flow output indication.

Power Supply: 12-42.4 VDC, 0.25 A @ 24 VDC; 12-36 VAC.

Electrical Connection: Removable terminal block, model-selectable 1/2" female NPT conduit connection, PG 16 gland, or PG 16 gland with (2) 10' (3 m) 9-conductor 22 AWG rated cable; accessory cable length up to 200' (61 m) optional.

Display: 2" (5.08 cm) x 2" (5.08 cm) graphic LCD with backlight.

Conductivity: >20 microsiemens.

Housing: Powder-coated aluminum casting.

Enclosure: NEMA 6P (IP68) (non-display models); NEMA 4X (IP66) (LCD optional).

Certifications: UL, CE, NSF/ANSI 61 and 372.


Communication (-COM option)

Type: BACnet MS/TP or Modbus? RTU communication protocol (default disabled, display selectable).

Supported Baud Rates: 9600, 19200, 38400, 57600, 76800, or 115200 bps (display selectable).

Device Load: 1/8 unit load.

Additional Specifications

Applicable Pipe Materials: Common plastic and metal pipes; such as carbon steel, stainless steel, copper, UPVC/PVDF, galvanized steel, mild steel, and brass*.

Pipe Sizes: IEF-HEX-X: 4 to 10" (101 to 254 mm); IEF-SX-X: 4 to 36" (101 to 914 mm).


Installation Position Requirements: Upstream >10 times diameter, downstream >5 times diameter.


*Brass fittings and pipes are not used with NSF-certified models.

Industry Category Electronic Components & Supplies/Sensors/Displacement Sensors
Product Category
Brand: DWYER
Spec: IEF-SN-CND
Stock: 122
Manufacturer:
Origin: China / Shanghai / Jinganqu
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 桐乡市| 夏津县| 衡水市| 郁南县| 武邑县| 锡林浩特市| 滨海县| 宁远县| 连南| 遂昌县| 佛山市| 东源县| 岳普湖县| 绥棱县| 馆陶县| 富锦市| 深水埗区| 萨迦县| 三门峡市| 庐江县| 岫岩| 隆昌县| 濮阳市| 丰镇市| 纳雍县| 缙云县| 玛曲县| 基隆市| 广丰县| 正定县| 屏东市| 澄江县| 江北区| 沂源县| 皋兰县| 鹤庆县| 监利县| 玉龙| 德江县| 新安县| 长寿区|