Shaft connection type gate opening sensor

Price:¥1999.99
Industry Category: Instruments & Meters/Specialized Instruments/Other Specialized Instruments
Product Category:
Brand: 徐州海河
Spec: HZW


Contact Info
  • Add:徐州經(jīng)濟(jì)技術(shù)開(kāi)發(fā)區(qū)聯(lián)東U谷-徐州經(jīng)開(kāi)智造園一期15號(hào)樓1層15#02, Zip:
  • Contact: 高經(jīng)理
  • Tel:0516-87939789
  • Email:2811207280@qq.com

Other Products

Description
Additional Information

The HZW series gate position meter (gate opening sensor) is specifically designed for gate measurement characteristics, utilizing photoelectric or contact encoders, and is manufactured with precision variable-speed mechanisms internally. It offers multiple output signal options for users to choose from, including parallel Gray code, serial RS485, 4-20mA standard analog signals, and SSI synchronous serial signals. This sensor is easy to install, highly adaptable, stable, and reliable, integrating detection and A/D conversion into one unit, with a power-off memory tracking function. It is suitable for measuring the lifting height of various gates (such as flat gates, radial gates, miter gates, gantry cranes, bridge cranes, etc.). Its functionality, features, and reliability are highly trusted and praised by water conservancy and hydropower engineering technicians.


I. Main Technical Specifications:

The technical specifications of this sensor mainly depend on the encoder used. Optional encoders include: HGD65535 photoelectric encoder, HJZ8192 contact encoder, or various imported encoders.

1. HGD65535 Photoelectric Encoder (Patent No.: ZL 2010 2 0521497.9)

Encoding Characteristics: Encoding, 1024 sets of codes per cycle, continuous 64 cycles (i.e., 1024*64)

Operating Voltage: DC12-24V

Dimensions: Main body diameter 60, length 64

Operating Environment Temperature: -20℃ to +75℃ (non-condensing)
Storage Environment Temperature: -25℃ to +80℃

Power Consumption: ≤70mA (varies with output signal and supply voltage)

Protection Level: IP64

Output Signals: A-4-20mA; B-Parallel Gray Code; M-RS485; S-Serial SSI Signal

2. HJZ8192 Contact Encoder

Encoding Characteristics: 128 sets of codes per cycle, continuous 64 cycles (i.e., 128*64)

Operating Voltage: Not exceeding DC30V

Dimensions: See the figure below

Operating Environment Temperature: -30℃ to +85℃ (non-condensing)
Relative Humidity: <90% (40℃)

Power Consumption: ≤40mA (determined by the decoding circuit)

Protection Level: IP64

Output Signals: A-4-20mA; B-Parallel Gray Code; M-RS485; S-Serial SSI Signal

3. JX8192 Mechanical Encoder

Encoding Characteristics: 32 sets of codes per cycle, continuous 256 cycles (i.e., 32*256)

Operating Voltage: DC12V

Dimensions: See the figure below

Operating Environment Temperature: -20℃ to +75℃ (non-condensing)
Storage Environment Temperature: -25℃ to +80℃

Power Consumption: ≤40mA

Protection Level: IP64

Output Signals: A-4-20mA; B-Parallel Gray Code; M-RS485; S-Serial SSI Signal

4. 12*12 Magnetoelectric Encoder

Encoding Characteristics: Encoding, 4096*4096

Operating Voltage: DC12-24V

Dimensions: See the figure below

Operating Environment Temperature: -20℃ to +75℃ (non-condensing)
Storage Environment Temperature: -25℃ to +80℃

Power Consumption: 29mA at 12V power supply; 16mA at 24V power supply. This parameter may vary with output interface and supply voltage.

Protection Level: IP65

Output Signals: A-4-20mA; M-RS485; S-Serial SSI Signal

Gate Position Meter Installation*Usage and Precautions:

1. This sensor is a high-precision instrument. Do not strike, drop, or collide with it during installation.

2. Connections between the sensor and external components should avoid rigid connections. Instead, use couplings, connecting gears, or synchronous belts for transmission.

3. During installation, ensure that the allowable axial load is not exceeded. Do not exceed the limit load.

4. Do not exceed the encoder's maximum rotational speed. Exceeding this limit may result in loss of electrical signals.

5. Ensure correct wiring. Incorrect wiring may damage the internal circuit of the sensor.

6. Do not bundle the sensor's output wires with power lines or transmit them through the same conduit. Avoid using near distribution panels to prevent interference.

Industry Category Instruments & Meters/Specialized Instruments/Other Specialized Instruments
Product Category
Brand: 徐州海河
Spec: HZW
Stock:
Origin: China / Jiangsu / Xuzhoushi
About Toocle.com -  Toocle Partnership -  Toocle Services -  Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 天峻县| 台南市| 威远县| 南部县| 岳阳市| 湟中县| 扶风县| 山东省| 怀安县| 丹阳市| 麦盖提县| 铜梁县| 庆城县| 襄垣县| 和龙市| 绥德县| 巴里| 察隅县| 抚顺市| 和平区| 额敏县| 共和县| 兴安县| 樟树市| 嵊泗县| 伊金霍洛旗| 玛纳斯县| 新民市| 基隆市| 永州市| 凤城市| 大方县| 伊金霍洛旗| 个旧市| 舞钢市| 高雄市| 桂阳县| 连南| 株洲市| 桃园县| 烟台市|