φ70mm (inner) galvanized metal bellows for pre-tensioning of precast beams, nationwide direct sales from the manufacturer.

Price:Negotiable
Industry Category: Construction & Building Materials
Product Category:
Brand: 衡水長江預(yù)應(yīng)力
Spec: 70


Contact Info
  • Add:河北衡水北方工業(yè)基地園區(qū)東路269號, Zip: 053000
  • Contact: 高晴
  • Tel:15297607517
  • Email:1518498187@qq.com

Other Products

Description
Additional Information

φ70mm (inner diameter) galvanized metal bellows for pre-tensioning of precast beams - nationwide direct sales by manufacturer

Prestressed galvanized bellows are widely used in post-tensioned prestressed concrete engineering as protective sleeves for prestressing tendons (strands, wires, etc.). Their construction quality directly affects the safety and durability of the prestressed structure. Below is a detailed construction process and precautions.


1. Pre-construction Preparation

1.1 Material Inspection

  • Bellow quality: Check for uniform zinc coating without damage, φ70mm (inner diameter) galvanized metal bellows for pre-tensioning of precast beams - nationwide direct sales by manufacturer ensure no crushing or deformation of the pipe body.
  • Sealing performance: Ensure all joint accessories (such as connecting sleeves, waterproof tape) are complete to prevent grout leakage.
  • Specification matching: The bellows diameter should meet design requirements, typically 5~10mm larger than the prestressing tendon diameter.

1.2 Tool Preparation

  • Cutting machine (special bellow cutting tools to avoid burrs)
  • Waterproof tape/heat-shrink tubing (for joint sealing)
  • Tie straps/rebar supports (to fix bellow position)
  • Positioning measuring instruments (ensure accurate bellow coordinates)

2. Bellows Installation

2.1 Positioning and Fixing

  • Position according to design coordinates: Use rebar supports or special positioning bars to fix bellows, φ70mm (inner diameter) galvanized metal bellows for pre-tensioning of precast beams - nationwide direct sales by manufacturer spacing ≤1m (reduced to 0.5m in curved sections).
  • Curved section treatment: Adopt smooth transitions, avoid sharp bends (minimum bending radius ≥30 times pipe diameter).
  • Height control: The centerline of bellows should align with the designed position of prestressing tendons, deviation ≤5mm.

2.2 Connection and Sealing

  • Straight pipe connection: Use one-size larger bellows for sleeve connection, overlap length ≥30cm, wrap waterproof tape or heat-shrink seal at joints.
  • Branch pipe connection: Use special tees or cross fittings to ensure sealing.
  • Vent hole setup: Reserve vent holes (Φ20mm plastic pipe) at the highest points of curves to prevent air accumulation during pouring.

2.3 Anti-blocking Measures

  • Insert temporary lining pipes (such as PE pipes or rubber rods), remove φ70mm (inner diameter) galvanized metal bellows for pre-tensioning of precast beams - nationwide direct sales by manufacturer after initial concrete setting to prevent grout leakage blockage.
  • Check pipeline patency before pouring, use high-pressure air guns or hole cleaners for clearing.

3. Concrete Pouring Protection

  • Vibration avoidance: Vibrators should not directly contact bellows to avoid damage or displacement.
  • Leakage inspection: Focus on monitoring joints, immediately flush pipes with water if leakage is detected.
  • Protection during curing: Avoid external impact or welding operations that could damage the zinc coating.

4. Prestressing Tendon Installation

  • Installation timing: Proceed after concrete strength reaches 75% of design value.
  • Lubrication to reduce friction: Apply special lubricant (such as wax-based materials) inside bellows before installation.
  • Anti-rust measures: Temporarily seal exposed ends with waterproof tape after strand installation.

5. Common Issues and Solutions

Issue

Cause

Solution

Bellow crushing/deformation

Excessive pressure during pouring

Increase support density, control vibration distance

Grout leakage blocking conduit

Poor joint sealing

Use double-layer tape + heat-shrink tubing for enhanced sealing

Difficult tendon installation

Conduit misalignment or local blockage

Pre-clean conduits, correct positioning

Industry Category Construction & Building Materials
Product Category
Brand: 衡水長江預(yù)應(yīng)力
Spec: 70
Stock:
Origin: China / Hebei / Hengshuishi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Me 金溪县| 潼关县| 利津县| 垫江县| 宁陕县| 石城县| 湘潭市| 建宁县| 门头沟区| 怀远县| 邢台市| 龙江县| 长武县| 正镶白旗| 凤翔县| 垦利县| 余庆县| 环江| 砀山县| 屯昌县| 龙里县| 河曲县| 通州市| 信丰县| 仪陇县| 五指山市| 开远市| 拜城县| 浦北县| 邹城市| 都昌县| 凤城市| 乌恰县| 石狮市| 东平县| 临泽县| 广东省| 五峰| 庆阳市| 常熟市| 巍山|