KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control System

Price:¥999
Industry Category: Electrical & Electronics
Product Category:
Brand: KZJNK
Spec: KZJNK-L-0.4-30A


Contact Info
  • Add:柳市柳黃路1600, Zip:
  • Contact: 吉經(jīng)理
  • Tel:0577-27877837
  • Email:2392076794@qq.com

Other Products

Description
Additional Information

Intelligent automation control function, featuring a unique astronomical time control that automatically simulates the local sunlight pattern, intelligently controlling the daily lighting start and stop times without the need for manual adjustments due to seasonal changes. KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control SystemOn-site, the lighting current, voltage, power factor, electricity metering data, and real-time operation control can be observed via the LCD touch screen, making it more convenient for staff to operate and inspect locally. It also provides RS232 or RS485 interfaces for remote transmission and control of lighting data.



Technical Specifications:
Operating Voltage: 220V±20% AC, 50Hz/60Hz, 220V±20% DC;
Rated Operating Current (per phase): 20A, 30A, 40A, 50A;
Voltage Setting Range: 170V - 255V;
Output Voltage Accuracy: ±15%;
Timing Accuracy: ±1 second;
Clock Accuracy: ±50ppm;
Full Voltage Preheating Start Time: 1-9 minutes adjustable;
Overload Capacity: Continuous overload of 30% for extended periods;
Cooling: Forced air cooling;
Operation: Suitable for environments with gases and dust;
Operating Temperature: -10℃ to +55℃ (special requirements must be specified);
Storage Temperature: -55℃ to +80℃;
Relative Humidity: ≤95%

KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control System Performance Features:
Motor temperature, noise, operation;
Time-based control: The intelligent street light energy-saving controller can operate based on time segments, meeting the control requirements of different types of street lights.
Dusk-to-dawn time control function: Automatically turns lighting fixtures on/off based on changes in urban light levels.
Adaptive voltage regulation during startup: The microprocessor automatically identifies the load characteristics during startup, controlling the rise rate of voltage and current to achieve optimal conditions when starting the lights.

Installation of Urban Street Light Management Energy-Saving Monitoring System Device:
1. Install indoors or on a platform, at least 20 cm above the ground;
2. Operating temperature: -10°C to +40°C, relative humidity not exceeding 85%, avoid flammable, explosive, and corrosive gases;
3. Avoid environments with water droplets, steam, and oily dust;
4. Installation should be vibration-free;
5. Installation should be secure, with the device casing reliably grounded, and vertical tilt should not exceed 5 degrees;
6. Sufficient cooling and maintenance space should be left around and above the energy-saving device;
7. Before powering on, carefully check all wiring to ensure it is in good condition and tight; the air switch should be turned off.
Note: This product can only be used for purposes approved in this manual. Unapproved use may cause fires, electric leakage, or other accidents.
If customers have special usage requirements, please consult with our company before placing an order.
Main Circuit Operation Process:
1. First, through a high-precision time controller, automatically adjust the daily on/off time control according to seasonal changes.
2. When the time controller activates the main circuit to supply power to the lighting, the first 5-8 minutes (pre-set) operate at full voltage to ensure the bulbs are fully preheated and started, reaching normal working conditions.
3. After the preheating period, the microprocessor controls the phase shift of the thyristor to smoothly enter the ramp-down period, then automatically transitions to the first-level energy-saving state, maintaining stable energy-saving operation.
4. When used for road lighting control, due to the characteristics of fewer vehicles and people in the late night, in addition to setting the first-level energy-saving mode, it is advisable to adopt the second-level energy-saving mode for the late night to achieve better energy-saving effects.

Industry Category Electrical & Electronics
Product Category
Brand: KZJNK
Spec: KZJNK-L-0.4-30A
Stock: 200
Manufacturer:
Origin: China / Zhejiang / Wenzhoushi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Me 福清市| 壶关县| 沁水县| 汪清县| 江达县| 沅江市| 萍乡市| 武威市| 阿巴嘎旗| 友谊县| 个旧市| 哈尔滨市| 加查县| 高碑店市| 蓝山县| 万州区| 札达县| 汽车| 安达市| 桑日县| 黄冈市| 郯城县| 阳朔县| 福建省| 丰县| 卓资县| 印江| 新绛县| 都安| 定安县| 从江县| 蚌埠市| 黔东| 大埔县| 北辰区| 布尔津县| 聂拉木县| 湖口县| 临澧县| 连城县| 保靖县|