尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control System - China Supplier
China KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control System - China Supplier China KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control System - China Supplier China KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control System - China Supplier

KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control System

Price:¥999
Industry Category: Electrical Equipment & Supplies/Industrial Control Systems/PLC Controllers
Product Category:
Brand: KZJNK
Spec: KZJNK-L-0.4-30A


Contact Info
  • Add:柳市柳黃路1600, Zip:
  • Contact: 吉經(jīng)理
  • Tel:0577-27877837
  • Email:2392076794@qq.com

Other Products

Description
Additional Information

Intelligent automation control function, featuring a unique astronomical time control that automatically simulates the local sunlight pattern, intelligently controlling the daily lighting start and stop times without the need for manual adjustments due to seasonal changes. KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control SystemOn-site, the lighting current, voltage, power factor, electricity metering data, and real-time operation control can be observed via the LCD touch screen, making it more convenient for staff to operate and inspect locally. It also provides RS232 or RS485 interfaces for remote transmission and control of lighting data.



Technical Specifications:
Operating Voltage: 220V±20% AC, 50Hz/60Hz, 220V±20% DC;
Rated Operating Current (per phase): 20A, 30A, 40A, 50A;
Voltage Setting Range: 170V - 255V;
Output Voltage Accuracy: ±15%;
Timing Accuracy: ±1 second;
Clock Accuracy: ±50ppm;
Full Voltage Preheating Start Time: 1-9 minutes adjustable;
Overload Capacity: Continuous overload of 30% for extended periods;
Cooling: Forced air cooling;
Operation: Suitable for environments with gases and dust;
Operating Temperature: -10℃ to +55℃ (special requirements must be specified);
Storage Temperature: -55℃ to +80℃;
Relative Humidity: ≤95%

KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control System Performance Features:
Motor temperature, noise, operation;
Time-based control: The intelligent street light energy-saving controller can operate based on time segments, meeting the control requirements of different types of street lights.
Dusk-to-dawn time control function: Automatically turns lighting fixtures on/off based on changes in urban light levels.
Adaptive voltage regulation during startup: The microprocessor automatically identifies the load characteristics during startup, controlling the rise rate of voltage and current to achieve optimal conditions when starting the lights.

Installation of Urban Street Light Management Energy-Saving Monitoring System Device:
1. Install indoors or on a platform, at least 20 cm above the ground;
2. Operating temperature: -10°C to +40°C, relative humidity not exceeding 85%, avoid flammable, explosive, and corrosive gases;
3. Avoid environments with water droplets, steam, and oily dust;
4. Installation should be vibration-free;
5. Installation should be secure, with the device casing reliably grounded, and vertical tilt should not exceed 5 degrees;
6. Sufficient cooling and maintenance space should be left around and above the energy-saving device;
7. Before powering on, carefully check all wiring to ensure it is in good condition and tight; the air switch should be turned off.
Note: This product can only be used for purposes approved in this manual. Unapproved use may cause fires, electric leakage, or other accidents.
If customers have special usage requirements, please consult with our company before placing an order.
Main Circuit Operation Process:
1. First, through a high-precision time controller, automatically adjust the daily on/off time control according to seasonal changes.
2. When the time controller activates the main circuit to supply power to the lighting, the first 5-8 minutes (pre-set) operate at full voltage to ensure the bulbs are fully preheated and started, reaching normal working conditions.
3. After the preheating period, the microprocessor controls the phase shift of the thyristor to smoothly enter the ramp-down period, then automatically transitions to the first-level energy-saving state, maintaining stable energy-saving operation.
4. When used for road lighting control, due to the characteristics of fewer vehicles and people in the late night, in addition to setting the first-level energy-saving mode, it is advisable to adopt the second-level energy-saving mode for the late night to achieve better energy-saving effects.

Industry Category Electrical Equipment & Supplies/Industrial Control Systems/PLC Controllers
Product Category
Brand: KZJNK
Spec: KZJNK-L-0.4-30A
Stock: 200
Manufacturer:
Origin: China / Zhejiang / Wenzhoushi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 友谊县| 双牌县| 苏尼特右旗| 资中县| 肇东市| 搜索| 西贡区| 宜宾市| 砚山县| 凭祥市| 田林县| 孟连| 洛浦县| 崇明县| 泌阳县| 榆中县| 西乌| 嘉黎县| 苍南县| 玉屏| 乌苏市| 土默特右旗| 安顺市| 崇信县| 商丘市| 平舆县| 玛沁县| 酉阳| 富源县| 河南省| 大连市| 都江堰市| 平武县| 子长县| 寿光市| 九江市| 尉犁县| 新化县| 峨山| 卫辉市| 正宁县|