KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control System

Price:¥999
Industry Category: Electrical Equipment & Supplies/Industrial Control Systems/PLC Controllers
Product Category:
Brand: KZJNK
Spec: KZJNK-L-0.4-30A


Contact Info
  • Add:柳市柳黃路1600, Zip:
  • Contact: 吉經(jīng)理
  • Tel:0577-27877837
  • Email:2392076794@qq.com

Other Products

Description
Additional Information

Intelligent automation control function, featuring a unique astronomical time control that automatically simulates the local sunlight pattern, intelligently controlling the daily lighting start and stop times without the need for manual adjustments due to seasonal changes. KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control SystemOn-site, the lighting current, voltage, power factor, electricity metering data, and real-time operation control can be observed via the LCD touch screen, making it more convenient for staff to operate and inspect locally. It also provides RS232 or RS485 interfaces for remote transmission and control of lighting data.



Technical Specifications:
Operating Voltage: 220V±20% AC, 50Hz/60Hz, 220V±20% DC;
Rated Operating Current (per phase): 20A, 30A, 40A, 50A;
Voltage Setting Range: 170V - 255V;
Output Voltage Accuracy: ±15%;
Timing Accuracy: ±1 second;
Clock Accuracy: ±50ppm;
Full Voltage Preheating Start Time: 1-9 minutes adjustable;
Overload Capacity: Continuous overload of 30% for extended periods;
Cooling: Forced air cooling;
Operation: Suitable for environments with gases and dust;
Operating Temperature: -10℃ to +55℃ (special requirements must be specified);
Storage Temperature: -55℃ to +80℃;
Relative Humidity: ≤95%

KZJNK-L-0.4-30A Intelligent Street Light Energy-Saving Remote Control System Performance Features:
Motor temperature, noise, operation;
Time-based control: The intelligent street light energy-saving controller can operate based on time segments, meeting the control requirements of different types of street lights.
Dusk-to-dawn time control function: Automatically turns lighting fixtures on/off based on changes in urban light levels.
Adaptive voltage regulation during startup: The microprocessor automatically identifies the load characteristics during startup, controlling the rise rate of voltage and current to achieve optimal conditions when starting the lights.

Installation of Urban Street Light Management Energy-Saving Monitoring System Device:
1. Install indoors or on a platform, at least 20 cm above the ground;
2. Operating temperature: -10°C to +40°C, relative humidity not exceeding 85%, avoid flammable, explosive, and corrosive gases;
3. Avoid environments with water droplets, steam, and oily dust;
4. Installation should be vibration-free;
5. Installation should be secure, with the device casing reliably grounded, and vertical tilt should not exceed 5 degrees;
6. Sufficient cooling and maintenance space should be left around and above the energy-saving device;
7. Before powering on, carefully check all wiring to ensure it is in good condition and tight; the air switch should be turned off.
Note: This product can only be used for purposes approved in this manual. Unapproved use may cause fires, electric leakage, or other accidents.
If customers have special usage requirements, please consult with our company before placing an order.
Main Circuit Operation Process:
1. First, through a high-precision time controller, automatically adjust the daily on/off time control according to seasonal changes.
2. When the time controller activates the main circuit to supply power to the lighting, the first 5-8 minutes (pre-set) operate at full voltage to ensure the bulbs are fully preheated and started, reaching normal working conditions.
3. After the preheating period, the microprocessor controls the phase shift of the thyristor to smoothly enter the ramp-down period, then automatically transitions to the first-level energy-saving state, maintaining stable energy-saving operation.
4. When used for road lighting control, due to the characteristics of fewer vehicles and people in the late night, in addition to setting the first-level energy-saving mode, it is advisable to adopt the second-level energy-saving mode for the late night to achieve better energy-saving effects.

Industry Category Electrical Equipment & Supplies/Industrial Control Systems/PLC Controllers
Product Category
Brand: KZJNK
Spec: KZJNK-L-0.4-30A
Stock: 200
Manufacturer:
Origin: China / Zhejiang / Wenzhoushi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 儋州市| 崇文区| 灵寿县| 壶关县| 新建县| 壶关县| 巴东县| 合水县| 七台河市| 大连市| 永新县| 鄂托克旗| 淮滨县| 盖州市| 边坝县| 永济市| 永登县| 固原市| 横山县| 阿拉善左旗| 湖口县| 响水县| 呼玛县| 兴化市| 泰顺县| 裕民县| 汤阴县| 宁德市| 台中县| 呈贡县| 龙海市| 定结县| 庐江县| 六枝特区| 府谷县| 哈尔滨市| 长宁县| 牙克石市| 宁武县| 临武县| 临高县|