China Water Cooling and Heating Temperature Control Unit - China Supplier China Water Cooling and Heating Temperature Control Unit - China Supplier China Water Cooling and Heating Temperature Control Unit - China Supplier China Water Cooling and Heating Temperature Control Unit - China Supplier China Water Cooling and Heating Temperature Control Unit - China Supplier

Water Cooling and Heating Temperature Control Unit

Price:Negotiable
Industry Category: Transportation/Other Unclassified/Other Truck Parts
Product Category:
Brand: Ninewells
Spec: JRW-10QA


Contact Info
  • Add:深圳市龍崗區(qū)坪地街道年豐社區(qū)橫嶺中路1號(hào)第七棟, Zip: 518116
  • Contact: 李大紅先生
  • Tel:0755-29084657
  • Email:szkawai@yeah.net

Other Products

Description
Additional Information

Water Cooling and Heating Temperature Control Unit

Introduction

Water Constant Temperature – Water Cooling and Heating Temperature Control Unit. The heating method utilizes heat from the air to warm the water, eliminating the need for heating tubes. In this era of environmental protection and energy conservation, this unit fully meets market demands..

Unit Cooling Principle

The compressor operates, converting low-temperature, low-pressure gaseous refrigerant into high-temperature, high-pressure gaseous refrigerant, which enters the condenser. Part of the heat from the refrigerant inside the condenser is expelled by external cooling water or cooling fans. The refrigerant releases heat and liquefies into a high-temperature, high-pressure liquid, which then flows through a dryer filter for drying and filtration. It then enters the expansion valve for throttling (a rapid cooling process) and pressure reduction. The refrigerant liquefies into a low-temperature, low-pressure liquid and enters the evaporator for heat exchange. The low-temperature, low-pressure liquid refrigerant absorbs heat from the surrounding medium (water, oil) outside the evaporator. During the heat absorption process, the refrigerant temperature remains unchanged, while its volume changes. After absorbing heat, the low-pressure hydraulic refrigerant vaporizes into a low-temperature, low-pressure gaseous refrigerant and enters the compressor. It is compressed into a high-temperature, high-pressure gas and enters the condenser, thus completing the entire refrigeration cycle.

Unit Heating Principle

Based on the cooling principle, the compressor operates, converting low-temperature, low-pressure gaseous refrigerant into high-temperature, high-pressure gas, which passes through a four-way valve and a liquid storage tank. The refrigerant enters the condenser, where the heat inside is utilized to heat the water tank. The heated water can reach up to 90 degrees. The refrigerant releases heat and liquefies into a high-temperature, high-pressure liquid, which then flows through a dryer filter for drying and filtration. It enters the expansion valve for throttling (a rapid cooling process) and pressure reduction. The refrigerant liquefies into a low-temperature, low-pressure liquid and enters the evaporator for heat exchange. The low-temperature, low-pressure liquid refrigerant absorbs heat from the surrounding medium (water, oil) outside the evaporator. During the heat absorption process, the refrigerant temperature remains unchanged, while its volume changes. After absorbing heat, the low-pressure hydraulic refrigerant vaporizes into a low-temperature, low-pressure gaseous refrigerant and enters the compressor. It is compressed into a high-temperature, high-pressure gas and enters the condenser, thus completing the entire heating cycle.

Features

The Water Cooling and Heating Temperature Control Unit has eight major protection devices:1. Phase loss and reverse phase protection device; 2. Motor overload protection device; 3. High and low pressure protection device; 4. Automatic water shortage alarm device; 5. Low temperature and anti-freezing protection device; 6. Coil overheating protection device; 7. Insufficient water flow protection device; 8. Fully automatic temperature control system

Unit Performance

The unit is entirely manufactured using original parts supplied by market-recognized, high-quality brands, ensuring stable performance and continuous operation of this series.

Control System

1. Control components, microcomputer boards, single modules, PLCs, etc., use market-recognized brands such as LG, Bopu, Siemens, Schneider, and Mitsubishi.

2. To enhance the stability and safety of the Water Cooling and Heating Temperature Control Unit during use, the EU quality system management certification has been actively implemented during production and processing. Quality control of products from suppliers is rigorously managed step by step, and load specifications are strictly regulated. The unit's performance includes additional protection devices such as phase loss and reverse phase protection, motor overload protection, high and low pressure protection, automatic water shortage alarm, low temperature and anti-freezing protection.

After-Sales Service

1.One year free warranty, lifetime maintenance (excluding human factors, consumables, and force majeure).

2.Upon receiving written equipment repair notification from the customer, response and on-site repair within 36 hours in Guangdong Province, and 72 hours outside Guangdong Province.

3.After the warranty period, a separate service agreement can be arranged to ensure effective protection for users during equipment operation.

4.During the warranty period, if equipment failure is caused by product quality (excluding human factors), all costs will be borne by our company.

5.Outside the warranty period, costs incurred for equipment maintenance will be charged based on actual expenses.

Unit Technical ParametersAir energy water refrigeration heating machine set Technical Parameters

<極端>

130×75×120

<極端的>

42

<極端的>

-

Model
Model

Refrigeration Capacity
Refrigerati
ng capacity

Heating Capacity

Compressor
Compressor

Evaporator
Evaporator

Condenser
Condenser

Water Pump
water pump

Dimensions

Shape dimension

kcal/h

kw

kw

kw

hp

L

inch

m3/h

m3/h

kw

mpa

cm

JRW-01QA

2494

2.9

3.1

0.75

1

18

3∕4"

1.2

1000

0.37

0.18

75×62×90

JRW-02QA

4988

5.8

6.2

1.5

2

40

3∕4"

1.2

2000

0.37

0.18

88×65×105

JRW-03QA

7482

8.7

9.3

2.2

3

45

3∕4"

1.8

3000

0.37

0.18

104×67×110

JRW-04QA

9976

11.6

12.4

3

4

60

3∕4"

2.6

4000

0.37

0.18

120×60×115

JRW-05QA

12470

14.5

15.5

3.75

5

70

1

3

5000

0.75

0.18

JRW-06QA

14964

17.4

18.6

4.5

6

90

1

3.6

6000

0.75

0.18

135×80×135

JRW-08QA

19552

23.2

24.8

6

8

140

2"

5

8000

0.75

0.18

145×90×140

JRW-10QA

24940

29

31

7.5

10

160

2"

6

10000

1.5

0.18

155×95×150

JRW-12QA

29928

34.8

37.2

9

12

170

2"

7.5

12000

1.5

極端的>

0.18

160×100×160

JRW-15QA

37410

43.5

46.5

11

15

200

2"

9

15000

1.5

0.18

170×110×175

JRW-20QA

49880

58

62

15

20

300

2"

12

20000

2.極端的>

0.18

185×120×180

JRW-25QA

59856

69.6

77.5

18

25

300

2.5"

15

25000

2.2

0.18

190×125×185

JRW-30QA

74820

87

93

22.5

30

450

2.5"

18

30000

3

0.18

210×140×200

JRW-40QA

99760

116

124

30

40

600

2.5"

25

40000

3.75

0.18

220×150×210

JRW-50QA

124700

145

155

37.5

50

700

3"

32

50000

3.75

0.18

240×160×220

JRW-60QA

149640

174

186

45

60

800

3"

40

60000

3.75

0.18

270×170×240

JRW-40QAS

103200

120

126

30

40

-

2.5

26

40000

-

200×65×160

JRW-50QAS

129000

<極端的>

150

157.5

37.5

50

-

3"

30

50000

-

-

200×極端的>

165

JRW-60QAS

154800

180

189

45

60

-

4"

36

60000

-

-

250×65×165

JRW-70QAS

180600

210

220.5

52.5

70

-

4"

70000

-

-

255×65×165

JRW-80QAS

206400

240

252

60

80

-

4"

48

80000

-

-

280×65×180

JRW-100QAS

258000

300

315

75

100

-

4"

62

100000

-

-

320×65×180

JRW-120QAS

309600

360

378

90

極端的>

120

-

4"

74

120000

-

-

350×80×180

JRW-140QAS

361200

420

441

105

140

-

4.5"

86

140000

-

-

360×80×190

JRW-150QAS

399900

456

472.5

112

150

-

4.5"

92

150000

-

-

360×80×180

JRW-160QAS

426560

496

504

120

160

-

4.5"

106

160000

-

-

390×110×160

JRW-180QAS

479880

558

567

135

180

-

4.5"

112

180000

-

-

410×110×160

JRW-200QAS

533200

620

630

150

200

-

4.5"

118

200000

-

410×140×160

Note: 1. Refrigeration compressor: Maximum operating temperature 45°C, refrigerant used is R22. Refrigeration compressor: Support highest temperature  45 ℃、Refrigerant R22 for use.

2. Screw unit energy automatic control is 75%-50%-25%. Screw water chillers energy automatic control for 75%-50%-25%.

3. Evaporation temperature inlet water 12°C, evaporation temperature outlet water 7°C. Condensation temperature inlet water 30°C, condensation temperature outlet water 35°C. Evaporation temperature into the water 12 ℃、Evaporation temperature water 7 ℃、Cooling water temperature into 30 、Cooling water temperature for 35.

4. The above parameters are subject to change without prior notice. The above parameters are subject to change without prior notice.

Industry Category Transportation/Other Unclassified/Other Truck Parts
Product Category
Brand: Ninewells
Spec: JRW-10QA
Stock: 0
Origin: China / Guangdong / Shenshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 咸丰县| 肇庆市| 镇江市| 甘泉县| 永嘉县| 古浪县| 朝阳市| 盐山县| 乌什县| 上林县| 磐安县| 白沙| 水城县| 伊川县| 昌吉市| 忻城县| 四子王旗| 清河县| 揭阳市| 视频| 泰宁县| 吴堡县| 泰州市| 浠水县| 安多县| 顺昌县| 双桥区| 沭阳县| 方正县| 璧山县| 嵩明县| 锦屏县| 通州区| 宜川县| 台湾省| 子洲县| 宝鸡市| 小金县| 饶平县| 瑞昌市| 江华|