Overview of the Transmission Line Fault Real-Time Monitoring System TLKS-PMG-DSC

Price:Negotiable
Industry Category: Machinery & Equipment/Seals & Gaskets/O-Rings
Product Category:
Brand: 特力康
Spec: TLKS-PMG-DSC


Contact Info
  • Add:深圳市龍崗區(qū)龍崗街道清風(fēng)大道39號(hào)精密達(dá)產(chǎn)業(yè)園C棟C-9樓, Zip: 518116
  • Contact: 李女士
  • Tel:13682351635
  • Email:1920671927@qq.com

Other Products

Description
Additional Information

Product Aliases: Transmission Line Intelligent Fault Diagnosis System, Transmission Line Distributed Fault Diagnosis Device, Transmission Line Fault Location and Identification System, Transmission Line Trip Fault Intelligent Diagnosis Platform, Transmission Line Fault Real-time Monitoring System

Product Model: TLKS-PMG-DSC

I. Product Description:

Transmission Line Fault Intelligent Diagnosis System is an efficient solution based on distributed sensor technology. It enables comprehensive real-time monitoring of transmission lines, quickly locates the source of problems when faults occur, and provides precise location information to facilitate rapid action by power repair teams.


II. Working Principle:

Transmission Line Fault Intelligent Diagnosis System is an intelligent system that integrates advanced sensor technology, communication technology, and data analysis technology. By installing distributed sensors at key positions along transmission lines, it monitors critical parameters such as current, voltage, and temperature in real-time. When a fault occurs, it quickly collects fault signals and transmits the data to a data center via wireless networks for analysis and processing. The system accurately determines the location, type, and cause of faults, providing timely and accurate fault information to maintenance personnel. This significantly reduces fault detection and repair time, enhancing the reliability and stability of the power system.


III. Product Functions:

1. Determine the fault section based on power frequency fault current

2. Implement precise traveling wave location within the determined fault section

3. For transmission lines with complex network structures, install distributed fault diagnosis devices at branch points to divide the complex network into simpler single-line structures

4. Identify the cause of faults, distinguishing between lightning and non-lightning faults. It can also identify lightning strikes on ground wires, towers, and conductors in cases where no trip occurs


IV. Technical Parameters:

1. Ambient Temperature: -40℃ to +85℃

2. Relative Humidity: 0 to 100% RH

3. Storage Temperature: -40℃ to +85℃

4. Wind Speed: 0 km/h to 100 km/h

5. Line Load: System coupling power extraction normal working current range 20 to 1000A

. Compatibility: Capable of withstanding 500kV strong electric and magnetic fields, with reliable and stable electromagnetic compatibility


V. Summary:

The application of this system not only improves the operational efficiency and safety of the power system but also provides strong support for national economic development and the improvement of people's livelihoods. In the future, with continuous technological advancements and deeper applications, the Transmission Line Fault Intelligent Diagnosis System will play an even more important role in the power industry, contributing to the construction of a safer, more efficient, and intelligent power system.

Contact us for more details! 1/3/6/8/2/3/5/1/6/3/5 (same number on WeChat)

Customized products; quoted prices are reference market prices at the time of publication; actual prices are subject to discussion.


VI. Precautions:

1. During the customization process, protect the intellectual property rights of both parties to avoid infringement risks.

2. Conduct technical feasibility assessments of user customization requirements to ensure they can be achieved and met.

3. Regularly perform visual inspections, performance tests, and cleaning maintenance on the equipment to promptly identify and resolve issues.

4. Before installation, carefully read the product installation manual to understand the installation steps, required tools, and safety requirements.

5. After installation, perform system debugging and testing to ensure all functions operate normally and data is transmitted accurately.

Industry Category Machinery & Equipment/Seals & Gaskets/O-Rings
Product Category
Brand: 特力康
Spec: TLKS-PMG-DSC
Stock:
Origin: China / Guangdong / Shenshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 宜州市| 水城县| 泌阳县| 嵊泗县| 宁南县| 桑植县| 灵川县| 承德县| 宁晋县| 杨浦区| 临安市| 双辽市| 深水埗区| 商南县| 方正县| 宁晋县| 望奎县| 乌鲁木齐市| 京山县| 四平市| 修文县| 常熟市| 枣强县| 莱阳市| 贡觉县| 晴隆县| 城市| 佛冈县| 油尖旺区| 潜江市| 东乌| 吐鲁番市| 蓝山县| 济南市| 南乐县| 太白县| 公主岭市| 灌云县| 军事| 宝丰县| 东丽区|