尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China Supply ZLLP-M1-10-152-T Elevator Energy Saving Controller - China Supplier
China Supply ZLLP-M1-10-152-T Elevator Energy Saving Controller - China Supplier China Supply ZLLP-M1-10-152-T Elevator Energy Saving Controller - China Supplier China Supply ZLLP-M1-10-152-T Elevator Energy Saving Controller - China Supplier China Supply ZLLP-M1-10-152-T Elevator Energy Saving Controller - China Supplier China Supply ZLLP-M1-10-152-T Elevator Energy Saving Controller - China Supplier

Supply ZLLP-M1-10-152-T Elevator Energy Saving Controller

Price:999
Industry Category: Others
Product Category:
Brand: ZLLP-M1-10-152-T
Spec: ZLLP-M1-10-152-T


Contact Info
  • Add:西安市雁塔區(qū)翠華南路60號, Zip:
  • Contact: 張簡
  • Tel:15299505139
  • Email:

Other Products

Description
Additional Information

Overview of Building Equipment Monitoring System

The building equipment monitoring system monitors the operating conditions of the following equipment systems and performs automatic control based on set parameters to achieve convenient management, energy savings, and improved efficiency. This detailed plan is designed based on plumbing, heating, and electrical drawings, and the subsystems considered mainly include:

1. Monitoring of fresh air handling unit equipment (excluding humidifying valves and their actuators, air dampers and their actuators, water valves and their actuators, and all other valves and actuators);

2. Monitoring of air handling unit equipment (excluding humidifying valves and their actuators, air dampers and their actuators, water valves and their actuators, and all other valves and actuators);

3. Monitoring of supply and exhaust air system equipment;

4. Monitoring of water supply and drainage system equipment;

5. Monitoring of networked fan coil unit control systems;

6. Group control system for cooling and heat sources (integration interface);

7. Monitoring of lighting system equipment (integration interface for smart lighting and floodlighting);

8. Elevator control system (integration interface);

9. Clean air conditioning system (integration interface);

10. Power distribution system (integration interface).

For more product information or pricing, please call our company.

Product inquiry hotline: 152-0290-6680

Please contact Manager Zhang: 15202906680 (same as WeChat ID)

We are committed to providing you with project drawing design optimization and configuration plan quotations!!!

Product Model:

ZLLP-M1-11-152-T Cooling Pump Integrated Control Module

1. Integrated secondary circuit of chilled water pump electrical control cabinet

2. Manual/remote-automatic control; interlock control; pump group status display; pump group combination configuration and automatic wear balancing function; inverter control

3. Real-time tracking of pump group efficiency and recording

4. Self-check function; provides fault location and cause for pump group and electrical control box, facilitating quick maintenance

ZLLP-M1-10-152-T Elevator Energy-saving Controller

Monitors the status and faults of equipment such as elevators, fire pumps, and sprinkler pumps; 35mm standard rail-mounted installation

Water pump energy-saving controller;

Automatically controls pump start/stop based on corresponding liquid level signals; automatically selects start/stop pumps based on cumulative operating time; motor monitoring, energy-saving evaluation, energy-saving control, etc.; 35mm standard rail-mounted installation.

ZLLP-M1-21-279-T Air Conditioning Fresh Air Energy-saving Controller

1. Equipped with AT-BUS communication interface and multiple switch loop output interfaces

2. Enables system control and manual control functions for ventilation/exhaust fan controllers

3. Can collect branch sensor signals and execute corresponding control logic based on sensor signals

4. Switch loop protection function

5. Delay protection, scene programming

ZLLP-M1-11-145-T Chiller Unit Energy-saving Controller

1. Integrated secondary circuit of cooling pump electrical control cabinet

2. Used to collect various control and status points of the chiller unit; manual/remote-automatic control; interlock control; unit status display; butterfly valve control; unit combination configuration and automatic wear balancing function, etc.

3. Configurable operating modes: direct start, soft start, variable frequency start; self-check function, provides fault location and cause for the unit and electrical control box, facilitating quick equipment maintenance

Industry Category Others
Product Category
Brand: ZLLP-M1-10-152-T
Spec: ZLLP-M1-10-152-T
Stock: 3324
Manufacturer:
Origin: China / Shaanxi / Xianshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 阿图什市| 栾城县| 斗六市| 遂昌县| 安阳县| 班戈县| 马山县| 盐山县| 湄潭县| 通山县| 洮南市| 全州县| 保定市| 遂溪县| 防城港市| 姜堰市| 合江县| 金秀| 黄龙县| 全南县| 垫江县| 靖边县| 红桥区| 巢湖市| 古田县| 许昌县| 鄂州市| 通许县| 祁门县| 泰安市| 迁安市| 云霄县| 都昌县| 包头市| 澄城县| 白城市| 马尔康县| 江油市| 阳春市| 宁武县| 德兴市|