Mining Cable Comprehensive Flaw Detection Tester

Price:¥13800 /套
Industry Category: Electrical Equipment & Supplies/Wires & Cables/Other Wires & Cables
Product Category:
Brand: 凱爾
Spec: KEKDL型


Contact Info
  • Add:揚(yáng)州寶應(yīng)柳堡工業(yè)集中區(qū)范柳路55號(hào), Zip: 225800
  • Contact: 費(fèi)蘇強(qiáng)
  • Tel:86-0514-88557066
  • Email:yzkedq@163.com

Other Products

Description
Additional Information

KEKDL Type Mining Cable Comprehensive Flaw Detection Tester


Note: This device offers two voltage regulation methods for users to choose from  1. Manual voltage regulation   2. Electric voltage regulation
I. Product Overview:
      Coal mines are major users of cables. Due to the extremely harsh working conditions underground, the annual damage rate of various cables is relatively high. To save costs and reduce production expenses, mines generally have their own cable maintenance teams. However, due to limitations in testing equipment and techniques, flaw detection during the repair of comprehensive mining cables often falls short, with many resorting to the forced breakdown method, which significantly damages cable insulation.
       The KEKDL type mining cable comprehensive flaw detection tester is based on the partial discharge method, which does not damage the original structure of the cable. It can easily and accurately detect cable damage locations and also includes testing functions after repair, making it a highly reliable testing device for current coal mine cable maintenance operations.
II. Product Use:
      The KEKDL type mining cable comprehensive flaw detection tester is used for flaw detection of various mining cables up to 10KV and below on the surface of coal mines. It also performs DC withstand voltage tests and leakage current tests after cable repair. It is a versatile and practical common testing device that meets the requirements of the "Coal Mine Electrical Test Regulations."
III. Main Technical Parameters:
      1. Current voltage: Single-phase AC 220V, 50Hz
      2. Flaw detection DC output voltage: 0~30KV (customizable for special voltages)
      3. Cable flaw detection accuracy: Within ±50mm
      4. Test output DC voltage: 0~30KV (customizable for special voltages)
      5. Automatic withstand voltage test time: 0~999S (adjustable)
      6. Leakage current test range: 0~300 mA
      7. Main transformer rated capacity: 5.0KVA
      8. Rectification method: Single-phase half-wave
      9. Discharge sphere gap: 1~30mm (adjusted by handle screw rod)                        
    10. Dimensions: 1100×1000×1300mm (width × depth × height)
    11. Equipment weight: 120.00Kg                                       
IV. Equipment Operating Environmental Conditions:
      1. Ambient medium temperature: -15℃~+45℃;
      2. Relative air humidity: Not more than 85% (at 20℃±5);
      3. Altitude: Not exceeding 2500m;
      4. No explosive hazardous media in the surroundings, and no gases or dust that can corrode metals or damage electrical insulation;
      5. No significant impact or vibration, and no intrusion of rain or snow. 
V. Structural Features:
      1. This device consists of a control part (low voltage) and a high-voltage rectification, discharge, and testing section. Sufficient safety space is reserved between high and low voltage parts, and between high/low voltage and the casing;
      2. To ensure the safety of the equipment and personnel, high-voltage startup must be operated by designated personnel;
      3. During each flaw detection or withstand voltage test, the high voltage starts from zero and rises slowly. The voltage increase or decrease is controlled by buttons (manual type controlled by manual rotation of the voltage regulator), ensuring smooth voltage change rates and safe, simple operation;
      4. The DC withstand voltage test time can be automatically set by a digital timer (or manually controlled), ensuring accurate and reliable test timing;
      5. Leakage current can be measured at any time during the withstand voltage test as needed;
      6. The device has overcurrent and short-circuit protection, with startup pre-warning and overcurrent protection;
      7. The control panel includes a power switch, high-voltage start, high-voltage stop, voltage increase, and voltage decrease switches or buttons (voltage increase/decrease only available in electric voltage regulation type), as well as a digital timer relay for withstand voltage testing;
      8. The display panel has measuring meters for high voltage, leakage current, and low voltage total current, along with indicators for power, high voltage, timing, etc., a discharge sphere gap, and an observation window;
      9. Equipped with a dedicated high-voltage discharge rod for safe discharge after each flaw detection or test. The bottom of the box has a grounding mark.




Note: The product is continuously updated and improved during production. Product appearance images are for reference only (subject to the actual product). Changes may occur without prior notice.

Industry Category Electrical Equipment & Supplies/Wires & Cables/Other Wires & Cables
Product Category
Brand: 凱爾
Spec: KEKDL型
Stock:
Origin: China / Jiangsu / Yangzhoushi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 遂川县| 儋州市| 镇康县| 宣城市| 秭归县| 枣强县| 乌拉特中旗| 峨眉山市| 上饶市| 兴安盟| 宣城市| 康乐县| 高邮市| 吴旗县| 陈巴尔虎旗| 湟中县| 平定县| 铜鼓县| 垦利县| 栖霞市| 宁国市| 建平县| 溧阳市| 怀来县| 浪卡子县| 稷山县| 洛隆县| 武宣县| 宁津县| 清流县| 高清| 宁明县| 瑞安市| 察隅县| 潞城市| 盐边县| 武安市| 什邡市| 岢岚县| 漳平市| 施秉县|