尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China Emergency Drainage Device - China Supplier
China Emergency Drainage Device - China Supplier

Emergency Drainage Device

Price:Negotiable
Industry Category:
Product Category:
Brand:
Spec:


Contact Info
  • Add:洪湖市濱湖辦事處工業(yè)開發(fā)區(qū), Zip: 433200
  • Contact: 文紅霞
  • Tel:0716-2263888
  • Email:HHLTGS@163.COM

Other Products

Description
Additional Information

Model Description


Technical Description

1. Working Principle: When the accumulated water exceeds the screen, water flows into the emergency drain pipe, using the impact force of the water to flip the float, activating the drainage state of the device.
2. Installation: For double-deck floating roof tanks, always use the upper limit. For single-deck floating roof tanks, larger capacity tanks, or areas with higher rainfall, use the upper limit; otherwise, use the lower limit. General requirements are as follows: the lower edge of the single-deck floating roof guard should be 250mm above the liquid level inside the tank. For double-deck floating roofs, the height from the top surface of the float to the lower edge of the filter screen is generally 120mm. The installation location can be any unobstructed area on the floating roof.
3. During installation, remove the water seal tank and send it into the tank through the manhole. Insert the drain pipe from the top of the pontoon and place it on the installation bracket, then weld and assemble them together.
 
The design of the emergency drainage device is based on the local maximum rainfall and the load capacity of the floating roof under the condition of complete blockage of the central drain pipe to determine the number of units to be selected. The recommended number of units is as follows:

Tank Capacity (

m³/unit)

5000~10000

20000~30000

50000

100000

Number of Units

1~2

1~2

3~4

4~6

Model

Specification

L(mm)

Design Discharge

(m³/h)

Weight (Kg)

Single Deck

Double Deck

Single Deck

Double Deck

LTPS-200

DN200

1700

2000

40~50

230

242

Maintenance

Regularly inspect the filter screen to prevent clogging that may cause the emergency drainage device to malfunction. After the tank is put into operation (including after each tank cleaning), add no less than 100 liters of water to this device at once. The major maintenance interval for this device is no less than 10 years, which can be synchronized with the tank's major maintenance.

Industry Category
Product Category
Brand:
Spec:
Stock:
Origin: China / Hubei / Jingzhoushi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 杂多县| 岳普湖县| 渝中区| 荆门市| 杭州市| 苗栗县| 洱源县| 安岳县| 梅河口市| 安泽县| 佛坪县| 双鸭山市| 旺苍县| 麻阳| 东阳市| 贡觉县| 铅山县| 乡城县| 陆良县| 密山市| 宁武县| 洛宁县| 栖霞市| 武汉市| 兴国县| 高台县| 阳西县| 周口市| 夏津县| 马山县| 定陶县| 南涧| 冕宁县| 常州市| 车险| 织金县| 仪征市| 兴仁县| 河曲县| 崇阳县| 晴隆县|